Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Audiol Res ; 11(2): 263-274, 2021 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-34207894

RESUMO

BACKGROUND: There is no guideline for hearing compensation after temporal bone resection. This study aimed to retrospectively analyze surgical cases with reconstruction for hearing preservation after temporal bone malignancy resection and propose a new alternative to compensate for hearing loss. METHODS: We retrospectively reviewed the medical records of 30 patients who underwent lateral temporal bone surgery for temporal bone malignancy at our institution and examined their hearing abilities after surgery. RESULT: The hearing outcomes of patients with an external auditory meatus reconstruction varied widely. The mean postoperative air-bone gap at 0.5, 1, 2, and 4 kHz ranged from 22.5 dB to 71.25 dB. On the other hand, the average difference between the aided sound field thresholds with cartilage conduction hearing aid and bone conduction thresholds at 0.5, 1, 2, and 4 kHz ranged from -3.75 to 41.25. More closely located auricular cartilage and temporal bone resulted in smaller differences between the aided sound field and bone conduction thresholds. CONCLUSIONS: There is still room for improvement of surgical techniques for reconstruction of the auditory meatus to preserve hearing after temporal bone resection. The cartilage conduction hearing aid may provide non-invasive postoperative hearing compensation after lateral temporal bone resection.

2.
J Am Med Dir Assoc ; 22(6): 1168-1174, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33811828

RESUMO

OBJECTIVES: To obtain new insights into research questions on how executive function and social interaction would be observed to change after the introduction of hearing aids (HAs) in older people with hearing impairment. DESIGN: Multi-institutional prospective single-arm observational study. SETTING AND PARTICIPANTS: Outpatients with complaints of hearing difficulty who visited HA clinics between October 18, 2017, and June 30, 2019, in 7 different university hospitals in Japan. METHODS: The inclusion criteria of the study named Hearing-Aid Introduction for Hearing-Impaired Seniors to Realize a Productive Aging Society-A Study Focusing on Executive Function and Social Activities Study (HA-ProA study) were age ≥60 years and no history of HA use. A series of multi-institution common evaluations including audiometric measurements, the digit symbol substitution test to assess executive functions, convoy model as an index of social relations, and hearing handicap inventory for the elderly (HHIE) were performed before (pre-HA) and after 6 months of the HA introduction (post-HA). RESULTS: Out of 127 enrollments, 94 participants completed a 6-month follow-up, with a mean age of 76.9 years. The digit symbol substitution test score improved significantly from 44.7 at baseline to 46.1 at 6 months (P = .0106). In the convoy model, the social network size indicated by the number of persons in each and whole circles were not significantly different between pre- and post-HA; however, the total count for kin was significantly increased (P = .0344). In the analyses of HHIE, the items regarding the family and relatives showed significant improvement. CONCLUSIONS AND IMPLICATIONS: HA use could benefit older individuals beginning to use HAs in executive function and social interaction, though the results should be interpreted cautiously given methodological limitations such as a single-arm short 6 months observation. Reduction in daily hearing impairment would have a favorable effect on relationships with the family.


Assuntos
Função Executiva , Auxiliares de Audição , Idoso , Humanos , Japão , Pessoa de Meia-Idade , Estudos Prospectivos , Interação Social
3.
Auris Nasus Larynx ; 45(4): 686-692, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29157624

RESUMO

OBJECTIVE: Voice-aligned compression (VAC) is a method used in Oticon's hearing aids to provide more comfortable hearing without sacrificing speech discrimination. The complex, non-linear compression curve for the VAC strategy is designed based on the frequency profile of certain spoken Western languages. We hypothesized that hearing aids could be further customized for Japanese-speaking users by modifying the compression curve using the frequency profile of spoken Japanese. METHODS: A double-blind randomized controlled crossover study was performed to determine whether or not Oticon's modified amplification strategy (VAC-J) provides subjectively preferable hearing aids for Japanese-speaking hearing aid users compared to the same company's original amplification strategy (VAC). The participants were randomized to two groups. The VAC-first group received a pair of hearing aids programmed using the VAC strategy and wore them for three weeks, and then received a pair of hearing aids programmed using VAC-J strategy and wore them for three weeks. The VAC-J-first group underwent the same study, but they received hearing aids in the reverse sequence. A Speech, Spatial and Qualities (SSQ) questionnaire was administered before beginning to use the hearing aids, at the end of using the first pair of hearing aids, and at the end of using the second pair of hearing aids. RESULTS: Twenty-five participants that met the inclusion/exclusion criteria from January 1 to October 31, 2016, were randomized to two groups. Twenty-two participants completed the study. There were no statistically significant differences in the increment of SSQ scores between the participants when using the VAC- or the VAC-J-programmed hearing aids. However, participants preferred the VAC-J strategy to the VAC strategy at the end of the study, and this difference was statistically significant. CONCLUSION: Japanese-speaking hearing aid users preferred using hearing aids that were fitted with the VAC-J strategy. Our results show that the VAC strategy can be adjusted to the frequency profile of different languages and that participants expressed their subjective preference more clearly than was reflected in the SSQ scores. A similar language-specific strategy may improve user's satisfaction while using hearing devices, and this concept may be extended to implantable hearing devices. CLINICAL RESEARCH REGISTRATION NUMBER: R000023191.


Assuntos
Auxiliares de Audição , Perda Auditiva/reabilitação , Idioma , Software , Percepção da Fala , Idoso , Audiometria de Tons Puros , Estudos Cross-Over , Método Duplo-Cego , Feminino , Humanos , Japão , Masculino , Dinâmica não Linear
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...